Emploi
J'estime mon salaire
Mon CV
Mes offres
Mes alertes
Se connecter
Trouver un emploi
TYPE DE CONTRAT
Emploi CDI/CDD
Missions d'intérim Offres d'alternance
Astuces emploi Fiches entreprises Fiches métiers
Rechercher

Conception, realisation et evaluation d'une sonde matricielle a base de mems acoustiques pour de l'imagerie ultrasonore passive: application au suivi de l'ouverture de la barrière hemato-encephalique par voie ultrasonore // design, implementation, and ev

Tours
Université de Tours
Design
Publiée le 26 mars
Description de l'offre

Topic description

Les transducteurs ultrasonores micro-usinés sont des MEMS (MicroElectroMechanicalSystems) acoustiques que l'on utilise pour émettre et recevoir des ondes ultrasonores. Leur principale application concerne l'imagerie médicale. Il existe deux catégories de MEMS acoustiques, 1) les PMUT (Piezoelectric Micromachined Ultrasonic Transducers) pour lesquels l'actionnement du MEMS (ou micro-membranes) se fait au moyen d'un matériau piézoélectrique et 2) les CMUT (Capacitive Micromachined Ultrasonic Transducers) pour lesquels les micro-membranes sont actionnées par des forces électrostatiques. Un des principaux atouts du CMUT réside dans sa capacité à détecter des ondes ultrasonores de très faible amplitude, du fait qu'il s'agisse d'un récepteur capacitif (qui fonctionne comme un microphone audio), qui, par nature, apporte très peu de bruit électronique et fonctionne dans une très large bande de fréquences. Dans le cadre de travaux de recherche précédents, le laboratoire BioMAPS, associé avec le laboratoire GREMAN a eu l'opportunité de démontrer l'efficacité de ces technologies dans le cadre d'essais in-vitro, d'ouverture de la barrière hémato-encéphalique (BHE), puis pré-cliniques menés sur le petit animal [1][2]. Le protocole d'ouverture de la BHE consiste à injecter des microbulles que l'on actionne au moyen d'un faisceau ultrasonore basse fréquence (typiquement 1 MHz). Ces dernières, au contact du tissu cérébral, par vibration, vont ouvrir de manière réversible la barrière hémato-encéphalique (processus de sonoporation), et ainsi, permettre de laisser passer des agents thérapeutiques. Ce procédé de thérapie nécessite un contrôle extrêmement précis du processus de sonoporation. On écoute, pour cela, les ultrasons ré-émis par les microbulles, lesquelles s'étendent typiquement de 1 à 5 fois la fréquence ultrasonore d'excitation des micro-bulles. Dans le cadre des travaux antérieurs [1][2], menés avec un simple transducteur mono-élément nous avons été capable de détecter des ultrasons avec des niveaux de pression extrêmement bas (quelques centaines de Pascal) pour une bande de fréquence allant de 1 MHz à 8 MHz. Nous souhaitons étendre ces travaux (ANR SENSICAV -) afin de construire une matrice de transducteurs (taille 13x13 mm2) CMUT comportant typiquement une centaine d'éléments, avec comme bande de fréquence visée kHz-2MHz. Il s'agira d'utiliser deux matrices identiques afin d'exploiter les ultrasons ré-émis pour faire de l'imagerie acoustique passive, et ainsi, permettre de localiser la zone où les micro-bulles agissent et interagissent avec les tissus. Cette phase de localisation permettra d'affiner le positionnement du transducteur d'excitation basse fréquence (pilotage par un robot asservi par les matrices CMUT), et ainsi améliorer l'efficacité du traitement thérapeutique par un ciblage plus précis.
L'objectif de ce travail de thèse porte sur la partie conception, fabrication et intégration de la matrice CMUT, menée en collaboration avec la société VERMON partenaire du projet ANR SENSICAV.
L'objectif de ce travail de thèse porte sur la partie conception, fabrication et intégration de la matrice CMUT, menée en collaboration avec la société VERMON partenaire du projet ANR SENSICAV. Cela comprend plusieurs axes de travail :
-Utilisation de modèle électroacoustiques afin de concevoir les CMUT,
-Concevoir des masques pour la partie process microélectronique,
-Concevoir et développer les briques d'intégration 3D de la sonde matricielle,
-Caractériser les puces CMUT fabriquées,
-Tester et évaluer sur plateforme d'imagerie ultrasonore les sondes CMUT.
------------------------------------------------------------------------------------------------------------------------------------------------------------------------
------------------------------------------------------------------------------------------------------------------------------------------------------------------------

Micro-machined ultrasonic transducers are acoustic MEMS (MicroElectroMechanical Systems) used to emit and receive ultrasonic waves. Their main application is in medical imaging. There are two categories of acoustic MEMS: 1) PMUTs (Piezoelectric Micromachined Ultrasonic Transducers), where the actuation of the MEMS (or micro-membranes) is done using a piezoelectric material, and 2) CMUTs (Capacitive Micromachined Ultrasonic Transducers), where the micro-membranes are actuated by electrostatic forces. One of the main advantages of CMUTs lies in their ability to detect very low amplitude ultrasonic waves, as they are capacitive receivers (working like an audio microphone), which inherently produce very little electronic noise and operate over a very wide frequency band. As part of previous research, the BioMAPS laboratory, in collaboration with the GREMAN laboratory, had the opportunity to demonstrate the effectiveness of these technologies in vitro for blood-brain barrier (BBB) opening trials and pre-clinical studies on small animals [1][2]. The BBB opening protocol involves injecting microbubbles that are actuated by a low-frequency ultrasonic beam (typically 1 MHz). These microbubbles, upon contact with brain tissue, will reversibly open the blood-brain barrier through vibration (a process called sonoporation), thus allowing therapeutic agents to pass through. This therapeutic process requires extremely precise control of the sonoporation process. To achieve this, the re-emitted ultrasound waves from the microbubbles are listened to, which typically extend from 1 to 5 times the excitation frequency of the microbubbles. In previous work [1][2], conducted with a simple single-element transducer, we were able to detect ultrasound at extremely low pressure levels (a few hundred Pascals) across a frequency range from 1 MHz to 8 MHz. We aim to extend this work (ANR SENSICAV -) by developing a CMUT transducer matrix (13x13 mm²) typically consisting of about a hundred elements, targeting a frequency range of kHz to 2 MHz. The goal is to use two identical matrices to exploit the re-emitted ultrasound for passive acoustic imaging, thereby localizing the region where the microbubbles are acting and interacting with the tissues. This localization phase will help refine the positioning of the low-frequency excitation transducer (controlled by a robot driven by the CMUT matrices), thus improving the therapeutic treatment's effectiveness through more precise targeting.
The objective of this doctoral research focuses on the design, fabrication, and integration of the CMUT matrix, carried out in collaboration with VERMON, a partner in the ANR SENSICAV project. This includes several areas of work:

- Use of electroacoustic models to design the CMUTs,
- Designing masks for the microelectronic process,
- Designing and developing the 3D integration components for the matrix probe,
- Characterizing the manufactured CMUT chips,
- Testing and evaluating the CMUT probes on an ultrasound imaging platform
------------------------------------------------------------------------------------------------------------------------------------------------------------------------
------------------------------------------------------------------------------------------------------------------------------------------------------------------------

Début de la thèse : 01/10/

Funding category

Other public funding

Funding further details

ANR Financement d'Agences de financement de la recherche

Postuler
Créer une alerte
Alerte activée
Sauvegardée
Sauvegarder
Offre similaire
Fashion designer – women's capsule collection
Tours
Jasia Styleshop
Design
Offre similaire
Sneakers and luxury shoes design consultant
Tours
Audrey Demolis & Partners
Design
Offre similaire
Learning experience designer – designer d'expériences d'apprentissage (f/h)
Tours
Alternance
Excelia Group
Design
Voir plus d'offres d'emploi
Estimer mon salaire
JE DÉPOSE MON CV

En cliquant sur "JE DÉPOSE MON CV", vous acceptez nos CGU et déclarez avoir pris connaissance de la politique de protection des données du site jobijoba.com.

Offres similaires
Emploi Culture à Tours
Emploi Tours
Emploi Indre-et-Loire
Emploi Centre
Intérim Culture à Tours
Intérim Tours
Intérim Indre-et-Loire
Intérim Centre
Accueil > Emploi > Emploi Culture > Emploi Design > Emploi Design à Tours > CONCEPTION, REALISATION ET EVALUATION D'UNE SONDE MATRICIELLE A BASE DE MEMS ACOUSTIQUES POUR DE L'IMAGERIE ULTRASONORE PASSIVE: APPLICATION AU SUIVI DE L'OUVERTURE DE LA BARRIÈRE HEMATO-ENCEPHALIQUE PAR VOIE ULTRASONORE // Design, Implementation, and Ev

Jobijoba

  • Conseils emploi
  • Avis Entreprise

Trouvez des offres

  • Emplois par métier
  • Emplois par secteur
  • Emplois par société
  • Emplois par localité
  • Emplois par mots clés
  • Missions Intérim
  • Emploi Alternance

Contact / Partenariats

  • Contactez-nous
  • Publiez vos offres sur Jobijoba
  • Programme d'affiliation

Suivez Jobijoba sur  Linkedin

Mentions légales - Conditions générales d'utilisation - Politique de confidentialité - Gérer mes cookies - Accessibilité : Non conforme

© 2025 Jobijoba - Tous Droits Réservés

Les informations recueillies dans ce formulaire font l’objet d’un traitement informatique destiné à Jobijoba SA. Conformément à la loi « informatique et libertés » du 6 janvier 1978 modifiée, vous disposez d’un droit d’accès et de rectification aux informations qui vous concernent. Vous pouvez également, pour des motifs légitimes, vous opposer au traitement des données vous concernant. Pour en savoir plus, consultez vos droits sur le site de la CNIL.

Postuler
Créer une alerte
Alerte activée
Sauvegardée
Sauvegarder